Polyamines-based, film-forming blends

ADVANTAGES
RESIDUAL PRODUCTS
FINEAMIN
- FINEAMIN® products are blends that decompose in various parts of the system, according to temp. and system needs. They do not react in any harmful manner with anything inside the system. Part of them are are adsorbed on the crystalline compounds of calcium, facilitating their online cleaning.
- Using FINEAMIN® organic additives for steam water circuits will not harm the equipment as the resulting degradation products are in no case corrosive due to their very low quantities.
-
Thermal decomposition products: FINEAMIN® chemicals can be used in steam water circuits with pressures up to 220 bar and temperatures up to 540°C due to their very low degradation ratio. FINEAMIN chemicals generate ammonia and acetate in an almost insignificant quantity – as low as 1 ppb for 1 ppm dosed product.
CONVENTIONAL TREATMENT
Hydrazine, phosphates, ammonia
- Precipitation: Under high heat transfer or high pressure conditions, phosphate compounds interact with iron oxide and ionic phosphate disappears. This reaction generates a low solubility product that precipitates, forming the so called hideouts, often hard to remove and leading to corrosion.
- When using traditional methods, the plant life is shortened by uncontrollable water chemistry and severe corrosion generated by decomposition products of hydrazine, but also due to the accumulation of sludge if phosphate treatment is not properly conditioned with additional additives such as polymers.
- Thermal decomposition products: Hydrazine begins to decompose at approximately 200°C and a significant amount of ammonia is formed, attacking primarily copper and copper alloys from the condensate line and feedwater system. One of its substitutes, carbohydrazide, releases hydrazine and carbon dioxide in high temperature conditions.
ORK PLACE & ENVIRONMENT SAFETY
FINEAMIN
- FINEAMIN® industrial water treatment products are non-toxic! They can be handled by instructed personnel with the minimum, conventional protection equipment. They do not have any dangerous, long term effects on humans if handled with care and according to the Safety Data Sheet.
- FINEAMIN® does not involve any special measures for storage of dangerous products. FINEAMIN® anti- corrosion additives can be stored for up to 5 years, without any problems, in a ventilated space, respecting the required temperatures: 5°C to 45°C, along with other chemicals, in the same storage facility. It is not flammable and does not present an explosion risk.
-
FINEAMIN® chemicals are organic additives for water treatment that do not have long or short term impact on the environment. Up to 80% biodegradable.
CONVENTIONAL TREATMENT
- Oxygen scavengers such as hydrazine are extremely toxic chemicals, known to posses severe health threats. Short-term exposure of humans to high levels of hydrazine may determine eye irritation, headaches, nausea, seizures, damage to internal organs or nervous system. Long-term exposure can provoke cancer.
- Hydrazine hydrate is an easy flammable substance that can’t be stored together with metal oxides or porous materials, close to any sources of heat or ignition. Dedicated storage facilities are required: well ventilated, inert atmosphere, with explosion-proof electrical equipment and well equipped with retention tanks in case of accidental leaks.
- Hydrazine hydrate does not show signs of persistence or bio-accumulation potential, but it does involve inherent, high toxicity to aquatic organisms.